How to Use a Gauge Pressure Sensor to Measure Negative Pressure

2024-12-13

There are two types of pressure sensors used for negative pressure or vacuum pressure applications: gauge        sensors and absolute pressure sensors. The reference pressure is the differentiating factor between these 2        types of sensors. The diagram below illustrates how the different methodologies work.

In applications that rely on the principle of a vacuum, it is important to effectively measure negative  pressure (also known as vacuum pressure). There are two basic ways to do so:

  • Measure the amount of pressure below local atmospheric pressure [typically 14.7 pounds/ square inch            absolute (PSIA)]

  • Measure how much pressure is above absolute zero vacuum (0 PSIA)

Both methods of measurement utilize the same scale and pressure point. However, these two measurements will        yield differing results over time because one measurement's reference point is a fixed quantity (absolute zero vacuum), whereas the other relies upon a variable amount (atmospheric air pressure, which can fluctuate).

  1. In the case of a gauge sensor, either a single port or dual port model can be used. In the case of a dual port gauge sensor, the "lower pressure" port measures the negative or vacuum pressure.

  2. By accessing the "lower pressure" port, the user is mimicking applying positive pressure to the higher            pressure port as in pressure range.

  3. The advantage of using a gauge sensor is if the user wants to measure a vacuum smaller than the full            vacuum range 14.7 psi, such as -3 psi, using a lower range focusing on the negative pressure range is            more appropriate. This way, by using a smaller full-scale range pressure sensor, the user captures the            full-range of the vacuum pressure measurements, thus obtaining more resolution and more design            flexibility. For a single port gauge sensor, the single port is vented to the atmosphere.

For example, if a user is trying to measure the inhalation pressure in a respiratory application, the pressure range would be no more than 0.6 psi. If an absolute pressure sensor is used, only 4% of the pressure range would be used, hence wasting 96% of the sensor's calibrated range.

Measuring Pressure Below Local Atmospheric Pressure Sources

Vacuum pressure is typically measured in terms of psi or pounds per square inch vacuum (PSIV). This measurement is generally relative to the surrounding atmospheric pressure. Vacuum pressure transducers can convert the inner negative pressure contained by an application into an electrical signal, and from there into a precise measurement.

 

At 0 PSIV—which is the same as typical atmospheric pressure, or 14.7 PSIA—the electrical output of a vacuum pressure transducer is 0 VDC. At full-scale, vacuum (14.7 PSIV or 0 PSIA), the output generally increased to        about 5 VDC. A vacuum pressure transducer's output in volts increases proportionally to the increase in        vacuum or negative pressure. On the other hand, an absolute pressure transducer emits increased positive        voltage in proportion to decreasing vacuum.

Measuring How Much Pressure is Above Absolute Zero Vacuum Sources

The scale for absolute pressure begins at  the high vacuum point of 0 PSIA. Unlike measurements that rely on atmospheric pressure as their main reference point, this methodology allows for more consistent readings.

 

An absolute pressure transducer features an electrical output of 0 VDC at 0 PSIA and increases to 5 VDC when it        reaches full-scale pressure (14.7 PSIA). This output is expressed in positive voltage

Pressure Sensors that Measure Negative Pressure

Vacuum pressure transducers and absolute pressure transducers  measure the same thing using different points of reference. They are both crucial components for use in applications that require accurate and reliable negative pressure measurements for proper functionality  and optimal performance.

 

When attempting to measure negative air pressure, it's important to use the proper equipment and to have that equipment calibrated to yield correct readings. Even small discrepancies between measurement and actual vacuum level could lead to performance issues.

Examples of classic applications where negative pressure measurements are needed include negative wound pressure therapy, breathing applications, pump control/performance monitoring, HVAC applications such as        filter monitoring, and pressurized rooms such as cleanrooms and isolation rooms.